Air Handling Units (AHU)
Statfield is a premier air handling unit manufacturer, Our engineers advanced climate solutions that form the very heart of modern HVAC systems. Our air handling unit (AHU) range is designed to deliver exceptional thermal comfort, superior air quality, and remarkable energy efficiency for any space, from sprawling corporate offices to sensitive pharmaceutical cleanrooms. We go beyond simply moving air; we provide a complete, integrated system for conditioning your environment, ensuring it meets the exact standards your application demands.
Product Details & Technical Specifications
Statfield’s expertise as an fresh air unit is reflected in our diverse product portfolio, designed to address specific airflow and conditioning challenges. Our units are built around robust fan technology and precise control systems.
- D.I.D.W. (Double Inlet Double Width) Fans – The Air Movement Core
- C.F.A.U. (Compact Fresh Air Handling Unit) – The Complete Conditioning Solution
- Spare Nozzle : Impeller with
- Fan Speed: 600 RPM to 1650 RPM
- Flow Rate: 500 CMH to 150,000 CMH
- Pressure: 45 mm to 125 mm wc
- Power: 0.5 HP to 100 HP (Low to Medium Pressure)
- Working Temperature: 20°C to 60°C
- Impeller Design: Backward Curved / Inclined for optimal efficiency and stable performance.
This is the fully integrated air handling unit, a self-contained system ready for installation and operation.
- Fan Speed: 600 RPM to 1650 RPM
- Flow Rate: 500 CMH to 150,000 CMH
- Pressure: 45 mm to 125 mm wc
- Power: 0.5 HP to 100 HP
- Working Temperature: 20°C to 60°C
- Key Feature: Integrated Temperature and Humidity Control system for complete environmental management.
- Fan Speed: 750 RPM To 2000 RPM
- Flow Rate: 2000 CMH To 50,000 CMH
- Pressure: 45 mm To 150 mm wc
- Power: 0.5 HP To 30 HP
- Working Temperature: 20°C To 350°C
- Impeller Design: Backwards Curved / Inclined
Application
- Powder Curing Ovens
- Dryers
Optional Accessories & Spares:
Silencers
Damper
Expansion bellows
Anti Vibration Pads
Benefits of Choosing a Statfield AHU
- Superior Energy Efficiency: The heart of our units, the backward-curved impeller in our D.I.D.W. fans, is engineered for maximum aerodynamic efficiency, significantly reducing power consumption and operational costs.
- Precise Environmental Control: Our C.F.A.U. models offer integrated temperature and humidity control, creating a consistently perfect environment for occupant comfort or sensitive industrial processes.
- Exceptional Air Quality & Hygiene: Constructed with cleanable components and options for high-grade filtration, our AHUs ensure the delivery of fresh, clean air, which is crucial for healthcare, pharmaceutical, and commercial spaces.
- Robust & Reliable Operation: Built with industrial-grade materials, every ahu is designed for a long service life with minimal downtime, providing peace of mind and a lower total cost of ownership.
- Scalable and Flexible Design: With a vast performance range, our units can be tailored to everything from a compact office floor to a large industrial hall, ensuring you get a perfectly sized solution without compromise.
Frequently Asked Questions
What is the primary function of blowers and fans in HVAC systems?
Air Circulation: Moving air through ductwork to maintain comfortable temperatures
Ventilation: Exchanging stale indoor air with fresh outdoor air
Pressure Maintenance: Creating positive or negative pressure in specific areas
Filtration Support: Moving air through filter systems for air quality control
How do Air Handler (AHU) differ from simple fans or blowers?
AHUs are complete systems that include:
- Heating/Cooling Coils for temperature control
- Filtration Systems for air quality
- Humidification/Dehumidification components
- Mixing Boxes for fresh and return air
- Control Systems for automated operation
- Housing that contains all components
What types of fans are commonly used in HVAC systems?
- Centrifugal Fans: For high-pressure applications like ducted systems
- Axial Fans: For high-volume, low-pressure applications
- Plug Fans: For AHU and air handler applications
- Vane Axial Fans: For medium-pressure, high-efficiency needs
Which factors determine the right fan selection for an HVAC application?
- Airflow Requirements (CFM)
- Static Pressure needs
- Space Constraints
- Noise Limitations
- Energy Efficiency goals
- System Architecture (ducted vs. unducted)
What routine maintenance do HVAC fans and AHUs require?
- Filter Replacement or cleaning
- Belt Tension checks (for belt-driven units)
- Bearing Lubrication
- Cleaning of coils and fan blades
- Motor Performance monitoring
- System Performance verification
What building types do you typically serve?
- Commercial Offices and retail spaces
- Hospitals and healthcare facilities
- Schools and universities
- Hotels and residential buildings
- Industrial Facilities
- Data Centers and telecom facilities
Get in touch
Over the last 50 years Statfield has been a synonym for innovation in powder coating surface coating and material handling solutions. Going beyond just surface coating
- 1073/1,2,3, Pirangut, Pune – 412115, Maharashtra, India
- +91 9689914230 / +91 9881407180
- marketing@statfieldequipments.com